500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump

  • 1
  • 2

Brand Name : SANCHANG

Model Number : COS-F80-270

Certification : ISO9001

Place of Origin : CHINA

MOQ : 1 pcs

Price : Negotiated

Payment Terms : L/C, T/T

Supply Ability : 300pcs/month

Delivery Time : 45 working days

Packaging Details : Plywood Case

Flow Capacity : 500-750gpm

Delivery Head : 60-100m

Inlet/Outlet Dia. : DN125/DN80mm

Working Pressre : <1.5MPa

Liquid Temperature : 0-80 ℃

Application : Clean water, Sewage, Hot water, Corrosive liquid, Mining water

Material : Cast Iron, Cast Steel, S.S304, S.S316, Duplex S.S2205

Driven By : Electric Motor / Diesel Engine

Voltage : 380V/415V/440V/460V/660V

Speed : 2980/3560rpm

Seal : Gland packing/Mechanical seal

Frequency : 50 /60 Hz

Contact Now

Double Suction Split Case Fire Fighting Water Pump COS-F80-270 (500-750gpm 60-100m)

Description

A fire fighting water pump is a centrifugal pump which is used for pumping fire-fighting water. Fire-fighting pumps can be designed for transportable use (e. g. on fire-fighting vehicles or as portable fire pumps) or for stationary use (e. g. hydrants, sprinkler systems).

The XSF series Horizontal Split Case Fire Fighting Water Pumps are engineered for reliable operation upon stationary use. All fabricated parts are standardized and accurately machined for true alignment, increasing overall durability. Precision balancing of all rotating components provides mechanical dependability, reliable operation and minimal maintenance. Impellers are constructed with double inlets that practically eliminated end thrust while boosting operating efficiency.

Fire fighting water pumps are usually in idle status. They are only operated for testing water / water mist systems or foam systems, and in the event of fire. This is why reliable start-up and fast ramp-up to full pump power output (also after prolonged standstill) is of particular importance.

Features
* Stainless steel impellers and shaft as standard
* Comply to FM and/or UL standards (NFPA 20, UL448 and FM1311)

High efficiency
The shapes of impeller and pump casings are optimized to achieve the highest possible efficiency for the specific design flow rate and pressure head. Off design characteristics are optimized to give each pump a wide operating range, ensuring that cavitation limits are not exceeded.

Ease of maintenance
The pumps are easy to maintain as the upper half can be removed without dismantling pipe connections and driver components so that the alignment is not disturbed. In addition, our service department offers financially attractive service and maintenance contracts, which guarantee that downtime in pumping installations is kept to a minimum.

Durability
By using double suction impellers and double volute casings Sanchang supplies pumps with low vibration and noise levels. A double volute reduces radial thrust, resulting in longer service life for bearings and seals.


Parameters of COS-F series Split Case Fire Fighting Water Pump

Flow Capacity 500-750 gpm Delivery Head 60-100 m
Inlet/Outlet Dia. DN125/DN80 mm Working Pressure ≤ 1.5 MPa
Liquid Temperature 0 - 80 ℃ Driven By Electric Motor / Diesel Engine
Seal Type Mechanical seal / Gland packing Liquid Clean water or similar
Material of Construction Cast Iron / Cast Steel / S.S304 / S.S316 / Duplex S.S2205

500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump

500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump

Applications

Industrial fire fighting system,
Residential fire fighting system,
Commercial fire fighting system,
Ware house fire fighting system,
Boat & Sea platform fire fighting,

Factory fire fighting system.

Main Parts Configuration

To meet the NFPA20 standards, the pump was constructed with the following materials:

Parts Name Material of Construction (Comply with NFPA20)
Pump Case Ductile Iron
Shaft 40Cr / 35CrMo / 42CrMo/S.S420
Shaft Sleeve S.S304
Impeller S.S304/Bronze
Wearing Ring S.S304/Bronze
Bearing China Make/NSK/SKF
Seals PTFE Packing Seals/Mechanical Seals
We offer a variety of service activities
• Online Supporting before & after sales, on-site consulatin include installation & commissioning advices.
• Original spare parts - we provide stock control of spare parts for groups of pumps (total care maintenance). We are able to respond quickly and flexibly thanks to the availability of our own foundry.
• Witness Inspection & Performance testing in factory.
• Training of our worldwide customers in the field of installation, operation and maintenance.
500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump
500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump

Product Tags:

750gpm Fire Water Booster Pump

      

750gpm Diesel Engine Driven Fire Water Pump

      

100m Fire Water Booster Pump

      
Quality 500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump for sale

500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: CHANGSHA SANCHANG PUMP CO., LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)